Vitomax HS

A compact and efficient steam boiler

A high pressure steam boiler that is ideal for large industrial concerns. Provides a continuous supply of steam at an output of 0.5 to 4 t/h with an operating pressure extending from 6 to 20 bar. 

  • Large
    Industrial
  • Operating pressure
    6 - 20 bar
  • Steam output
    0.5 - 4 t/h
  • Continuous
    Steam
  • Exceptional
    Efficiency
  • Designed for
    Reliability
  • Energy saving
    Insulation
  • Made in
    Germany
  • Energy-saving thermal insulation
  • Large steam chamber with low load
  • High efficiency of up to 95.5 percent
  • Water-cooled burner entry point at the front and water-cooled rear reversing chamber
  • Low-stress design

Key Benefits


Due to their design and equipment level, Vitomax industrial/commercial steam boilers deliver the best possible conditions for meeting individual customer requirements in a broad range of applications. The detailed design of the Vitomax boilers and the company's vast experience in building industrial boilers ensure superior quality, high operational reliability and a long service life.

The comprehensive Vitomax product range from Viessmann includes steam boilers with a continuous steam output of up to 4 t/h with an operating pressure of 6-20 bar.

Our versatile Vitomax high pressure steam boilers are designed to fully meet the needs of large industrial concerns.

High pressure steam for industrial use

The boiler provides a continuous supply of steam at an output of 0.5 to 4 t/h whilst its operating pressure extends from 6 to 20 bar (up to 30 bar on request).

The lateral arrangement of the flame tube results in a highly compact boiler design that meets all the requirements for efficient steam generation.

Large steam chamber with low pipe load

The spacing between the smoke tubes, as well as from the smoke tubes to the boiler shell and to the flame tube, substantially exceed requirements.

The shearing force on the end face floors caused by different linear expansion in the smoke tubes and the flame tube is therefore extremely low.

The corner stays of the boiler are always arranged in pairs. As a result, forces are distributed throughout the boiler, reducing stress and increasing its service life.

Designed for larger industrial concerns

The Vitomax HS type 73B high pressure steam boiler is the ideal solution for large industrial concerns, such as those involved in food processing, fertilisers, construction material, paper, beverage, chemical and pharmaceuticals, as well as hospitals and refineries.

Saving energy and protecting the climate

Viessmann is well aware of its responsibilities for protecting the environment and conserving natural resources. Our company philosophy and products have been constructed with this duty in mind.

"Nothing is so good that it cannot be improved." This motto is reflected in Viessmann company principles. In this industry, Viessmann can rightfully claim to be the leader in quality and technology, and as such, aims to continually set new standards.

This applies in particular to our product range, which is closely geared towards significantly lowering the consumption of fossil fuels and gradually replacing them with sustainable sources of energy.

At around 40 percent, the heating market actually accounts for the largest proportion of energy consumption. The rest is shared by "goods transport", "personal transport" and "power". These values can also be applied approximately to other industrial countries. Rising energy costs mean that the emphasis is on reducing the consumption of fossil fuels as quickly as possible.

Reliable design

The spacing between the smoke tubes, as well as from the smoke tubes to the boiler shell and to the flame tube, are in compliance with statutory requirements. The shearing force on the end face floors caused by different linear expansion in the smoke tubes and the flame tube is therefore extremely low, guaranteeing a long service life for these steam boilers.

The corner stays of the boiler are always arranged in pairs. As a result, the forces are distributed throughout the boiler, reducing stress and increasing the service life. In every case, the values lie well below the limits permitted by the FDBR trade association.

Want more information about this product?

Product Data

Steam & waste heat boilers

Technical Guide Steam boilers

Variants

Vitomax 200-HS M75A

Vitomax 200-HS M73A

Vitomax 300-HS M93A

Vitomax 300-HS M95A

Vitomax 200-HS M75A

Vitomax 200-HS M73A

Vitomax 300-HS M93A

Vitomax 300-HS M95A

Overview

Vitomax 200-HS M75A

Type M75A, high pressure steam boiler, steam output: 5 to 26.0 t/h

Vitomax 200-HS M73A

Type M73A, high pressure steam boiler, steam output: 0.5 to 4 t/h

Vitomax 300-HS M93A

Type M93A, high pressure steam boiler in a low NOₓ design, steam output: 1 to 4 t/h

Vitomax 300-HS M95A

Type M95A, high pressure steam boiler in a low NOₓ design, steam output: 5 to 26.0 t/h

Want more information about this product?

Related Products

Vitomax LW
A robust, low pressure hot water boiler

A low pressure hot water boiler for permissible flow temperatures up to 110°C and constant temperature operation that is ideal for commercial and industrial premises and municipal offices.

Discover the Vitomax LW
  • Powered by
    Fuel Oil EL
  • Other fuel types
    Supported
  • Up to 
    8.8 MW
  • Flow temperature
    Up to 110°C
Discover the Vitomax LW
  • EfficiencyLabel
  • EfficiencyLabel